Why your lights are flickering

Flickering ranges from a cheap dimmer that does not suit the globe, right through to a loose connection at the switchboard. The difference matters.

  • 5.0 on Google
  • 24/7 emergency callout
  • Licence 82270

First, work out how much of the house is flickering

Most flickering turns out to be a dimmer that does not suit the LED globes wired to it, and that one is an annoyance rather than a danger. The version to take seriously is flickering that hits the whole house at once. That points at a loose connection carrying real current, or a problem on the supply side. Both of those make heat.

Before you ring anyone, spend two minutes working out the pattern:

  • One fitting only. Note whether it flickers on every dimmer setting or only low down, and whether it settles once it warms up. Try a different globe if you can reach it safely.
  • One room or one run of lights. That usually means one circuit, and usually one connection somewhere along it.
  • The whole house at once. Watch what else is happening. If it dips when the air conditioner, pool pump or bore pump starts, that is a voltage dip. If it flickers at random with nothing running, treat it as urgent.
  • Look outside at night. If the neighbours' lights and the street lights are doing it too, the problem is on the network, not in your house.
  • Stand near the switchboard. Do not open it. If the cover feels warm, or you hear buzzing or crackling, or you smell hot plastic, turn off the main switch and get an electrician out.

What it usually turns out to be

By a long way the most common cause is a dimmer and LED mismatch. Old dimmers were built for the load of a filament globe. A couple of LED globes drawing a few watts is not enough to keep them stable. You get flicker at low settings, a faint hum, or globes that will not go fully off. The fix is a dimmer designed for LED loads, matched to the globes. Sometimes the globes need changing too, because cheap ones will flicker on anything.

Next is a loose connection, either at the fitting, at a switch, or on a terminal in the switchboard. A loose terminal arcs, arcing makes heat, and heat makes the connection worse. This is the one that starts fires, and it is why flickering across several circuits gets a same day response from us rather than a booking next week.

Third is voltage dip from a big load starting. A pool pump, bore pump or air conditioning compressor pulls a large surge for a fraction of a second. A brief dim as it kicks in can be normal. A deep dip, or one that keeps going after the motor is running, usually means the circuit feeding it is undersized, the motor is drawing more than it should, or the switchboard is tired.

Up this way there are a couple of local causes worth naming. Ants and geckos nesting in outdoor fittings and enclosures is a common fault we find, particularly in the wet season. So is salt air corrosion on terminals anywhere near the coast between Craiglie and Port Douglas. After a storm, damaged overhead services and water in fittings cause flicker that will not fix itself.

What not to do

Do not keep using a dimmer or a fitting that buzzes, gets hot, or smells like hot plastic. Do not pull a light fitting down to have a look, because the wiring above a ceiling rose is live even with the switch off. Do not swap a dimmer yourself. Under Queensland law, testing and locating faults on live equipment is energised electrical work and is not a homeowner job. And do not ignore a whole house flicker because it is intermittent. Intermittent is exactly how a failing connection behaves right up until it fails properly.

What we do when we get there

We start by confirming the pattern, then measure. Voltage at the board and at the affected point, voltage drop under load, and a check of switchboard terminations for heat and discolouration. From there it is either a dimmer and globe match sorted on the spot, a connection remade and torqued properly, or proper fault finding across the circuit if it is hiding. If the flicker is on the network side we confirm it with readings and tell you what to report. Where the board itself is the weak point, we will explain what a switchboard upgrade would involve before you commit to anything.

Sources: WorkSafe Queensland, testing and energised electrical work; Electrical Safety Queensland, electrical safety during storms.

Straight answers

Lights flickering: your questions

Are flickering lights actually dangerous, or am I overreacting?

It depends entirely on the pattern. One lamp on a dimmer misbehaving is a nuisance and can wait for a normal booking. Lights across the whole house flickering together, or any flicker paired with a warm switchboard cover, a buzzing noise or a burnt plastic smell, means a connection is arcing and making heat. That is a same day job, not a next week job. If you get the smell or the heat, switch off the main switch and ring us on (07) 4099 3497. We run a 24 hour callout every day of the year.

Can I just change the dimmer or the globe myself?

Swapping a plug-in lamp globe is fine. Changing a globe in a fixed ceiling fitting is where people get into trouble, because the wiring above the fitting stays live even with the switch off, and older fittings up here often have brittle insulation from years of heat and humidity. Changing a dimmer is licensed electrical work and not something a homeowner can legally or safely do in Queensland. If your flicker is a dimmer and LED mismatch, it is a short job for us, and we will match the dimmer to the globes so it does not come back.

What will it cost to have flickering lights looked at?

The cost of having flickering lights looked at depends on the cause, because a dimmer swap and a whole house fault trace are not the same job. We go through the symptoms with you on the phone first, tell you the likely cause and what is involved, then quote once we have seen it. We do not publish rates. If it turns out to be a bigger fix, such as rewiring a light circuit or upgrading the board, you get that in writing before we start. No surprises at the end.

The neighbours' lights are flickering too. Is it still my problem?

Probably not. If lights up and down the street are dipping together, the issue is on the distribution network rather than inside your installation, and it needs to be reported to the network provider. We can still help by taking voltage readings at your board, which gives you something concrete to report rather than just saying the lights look funny. It is also worth checking after storm season, since damaged overhead services cause exactly this. If storm or flood water has been into your gear, verification testing by a licensed electrician is required before reconnection.

Lights flickering? We will find the actual cause.

Leave us a number and we will ring you back, or send the whole job through and we will quote it.

QLD Electrical Contractor Licence 82270 · 24/7 emergency callout

Request a call back

Request a call back

Leave a number and we will ring you back in office hours. No hold music, no phone tree.

We ring back during office hours, usually the same day. Something dangerous or no power at all? Reach us faster here.

SMS now